Your browser doesn't support javascript.
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters

Database
Main subject
Language
Document Type
Year range
1.
Heliyon ; 9(2): e13642, 2023 Feb.
Article in English | MEDLINE | ID: covidwho-2268555

ABSTRACT

Background: SARS-CoV-2 virus has undergone several mutations on its genome, since the onset of the pandemic. Multiple variants of concern (VOC) have emerged including Alpha, Beta, Gamma, and Delta with the more recent one being the Omicron (B.1.1.529). Specific rapid antigen tests (RADs) have been used for the detection of SARS-CoV-2. However, since the emergence of new VOCs, the performance characteristics of these RADs needs to be re-evaluated. Objectives: The main purposes of this clinical study were to determine the diagnostic sensitivity and specificity of the BOSON Rapid Antigen Test compared to the gold standard real time RT-PCR and to determine the ability of the RAD to accurately depict different VOC. Additionally, the cross reactivity to other viruses and pathogen, as well as, the possible interference of non Covid-19 hospitalized patients for various causes, were investigated. Results: A total of 623 individuals (symptomatic) were tested. The sensitivity, specificity and accuracy of the BOSON RAD was 95.27%, 100% and 98.45% (n = 448), meeting the WHO recommended standards. Additionally, the Delta (83.33%, Ct < 34) and Omicron (100%, Ct < 26) VOC were determined with high sensitivity. Also, there was no interference from hospitalized, non-Covid 19 patients, and no cross-reactivity was detected. Conclusions: The study showed that this RAD could rapidly identify individuals with SARS-CoV-2, including those with the new dominant Omicron VOC, with no cross reactivity from other pathogens.

2.
Diagn Microbiol Infect Dis ; 104(3): 115786, 2022 Nov.
Article in English | MEDLINE | ID: covidwho-1965608

ABSTRACT

The gold standard test available for detecting COVID-19 patients is Real Time RT-PCR. However, this method is expensive, needing special equipment and skilled laboratory staff. Recently, less expensive antigen tests have become available, that could easily and rapidly identify new COVID-19 cases. Our objective was to evaluate the Boson Rapid Antigen Test Card versus the RT-rtPCR, using samples taken both by laymen (self-testing) and professionals. The sensitivity, specificity and accuracy rates were, 98.18%, 100.00%, and 99.28%, respectively. The positive and negative predictive values were 100.00% and 98.82%, respectively. The detection rate for asymptomatic patients was 90.48%, and detection rate for Ct values ≥30 was 91.67%. Our results indicate a high coincidence rate between the Boson and the referencing RT-rtPCR method, meeting the performance standards recommended by the WHO. Therefore, this test could facilitate a fast self-testing screening method, for the detection of infected individuals.


Subject(s)
COVID-19 , Antigens, Viral/analysis , COVID-19/diagnosis , COVID-19 Testing , Humans , Reverse Transcriptase Polymerase Chain Reaction , SARS-CoV-2/genetics , Self-Testing , Sensitivity and Specificity
SELECTION OF CITATIONS
SEARCH DETAIL